INPUT:

  • PV Name(s)
    • Name of EPICS variable OR string array of EPICS variable names
    • Attention if you use an array of EPICS variable names!
      Mixed target data types arise as a result of a 2-D array with size of:
      number of names multiplied by size of largest data type of the group
  • Field Names
    • Optional
    • String array of static EPICS fields ("EGU", "DESC" etc.)
  • Timeout (3)
    • Optional
    • Timeout for Channel Access requests in seconds (1-255)
    • Default value: 3 seconds
  • Write Synchronous (F)
    • optional
    • TRUE:
      • writes value(s) after waiting for the end of record processing
    • FALSE:
      • default
      • writes value(s) without waiting for the end of record processing
  • Filter
    • optional
    • output filter  (this can save ressources and increase performance)
      Following values can be combined with OR:
      • PV indicators:
        • firstValueAsString = 1
        • firstValueAsNumber = 2
        • valueArrayAsNumber = 4
        • errorOut = 8
      • PV Info cluster:
        • pviElements = 16
        • pviValuesAsString = 32
        • pviValuesAsNumber = 64
        • pviStatusAsString = 128
        • pviStatusAsNumber = 256
        • pviSeverityAsString = 512
        • pviSeverityAsNumber = 1024
        • pviTimestampAsString = 2048
        • pviTimestampAsNumber = 4096
        • pviFieldNames = 8192
        • pviFieldValues = 16384
        • pviError = 32768
  • Error in (no error)

OUTPUT:

  • CA Lab data
    • Cluster with preinitialized data
  • Error out
    • Global I/O error

CaLabGet.vi and CaLabPut.vi can use "CA Lab data" cluster as input (first connector) to skip their automatically internal initialisation. Preinitialized CaLabGet.vi and CaLabPut.vi will start faster.