Highly sensitive method for detecting ion pairs in aqueous solution developed

Robert Seidel leads the Young Investigator Group Operando Interfacial Photochemistry.

Robert Seidel leads the Young Investigator Group Operando Interfacial Photochemistry. © HZB/Setzpfandt

The lithium chloride solution to be investigated was injected as an extremely fine stream of liquid into a vacuum chamber and analysed with soft X-ray emissions.

The lithium chloride solution to be investigated was injected as an extremely fine stream of liquid into a vacuum chamber and analysed with soft X-ray emissions. © HZB/Setzpfandt

Scientists of the Helmholtz-Zentrum Berlin, Freie Universität Berlin, Universität Heidelberg, and the University of Chemistry and Technology Prague have empirically detected a very specialised type of electron transfer in an aqueous salt solution, one which had only been predicted theoretically up to now. Based on these results, they now expect to have an extremely sensitive method for detecting ion pairs in solutions.

The scientists were successful in acquiring empirical evidence for what is referred to as electron-transfer-mediated decay (ETMD). “ETMD is a decay channel that becomes operative when a hole in the backbone of a molecule is filled by an electron from a neighbouring molecule. The energy released by this process is then utilized for ionisation of this or an additional neighbouring molecule”, explains Prof. Emad Flear Aziz.

“The decay is non-local and therefore is in competition with the much more frequently occurring processes of Auger emission and intermolecular Coulomb decay (ICD)”, explains co-author Dr. Robert Seidel. An electron hole in both these processes is filled by an electron from within their own respective molecules. The ETMD process was predicted earlier in 2001 and first detected in clusters of gas in 2011, according to the physicist.

The group utilised lithium chloride salt in an aqueous solution to detect the ETMD process, since neither Auger emission nor ICD decay are believed to occur with lithium ions in water. In this way, they increased the probability of the ETMD process and its detection.

The measurements took place at the Helmholtz-Zentrum BESSY II synchrotron in Berlin using the LiquidJet PES facility there. The lithium chloride solution to be investigated was injected as an extremely fine stream of liquid into a vacuum chamber and analysed with soft X-ray emissions.

“Since the strength of the ETMD process is strongly influenced by the separation between the host and neighbouring molecules, statements about the ion pairing can be made from the distribution and intensity of the ETMD spectrum”, explains Prof. Aziz. This means that ETMD puts a spectroscopic tool in the hands of scientists with which they can ascertain the thickness of a solvent envelope immediately surrounding an ion in an aqueous solution. The results of the study have been published in the renowned peer-reviewed journal Nature Chemistry.

The publication: Observation of electron-transfer-mediated decay in aqueous solution

Isaak Unger, Robert Seidel, Stephan Thürmer, Marvin N. Pohl, Emad F. Aziz, Lorenz S. Cederbaum, Eva Muchová, Petr Slavíček, Bernd Winter, and Nikolai V. Kryzhevoin.

Nature Chemistry (2017). DOI: 10.1038/nchem.2727

Freie Universität Berlin/red


You might also be interested in

  • Small powerhouses for very special light
    Science Highlight
    27.06.2024
    Small powerhouses for very special light
    An international team presents the functional principle of a new source of synchrotron radiation in Nature Communications Physics. Steady-state microbunching (SSMB) allows to build efficient and powerful radiation sources for coherent UV radiation in the future. This is very attractive for applications in basic research as well in the semiconductor industry.
  • New Method for Absorption Correction to Improve Dental Fillings
    Science Highlight
    24.06.2024
    New Method for Absorption Correction to Improve Dental Fillings
    A research team led by Dr. Ioanna Mantouvalou has developed a method to more accurately depict the elemental distributions in dental materials than previously possible. The used confocal micro-X-ray fluorescence (micro-XRF) analysis provides three-dimensional elemental images that contain distortions. These distortions occur when X-rays pass through materials of different densities and compositions. By utilizing micro-CT data, which provides detailed 3D images of the material structure, and chemical information from X-ray absorption spectroscopy (XAS) experiments conducted in the laboratory (BLiX, TU Berlin) and at the synchrotron light source BESSY II, the researchers have improved the method.
  • MXenes for energy storage: Chemical imaging more than just surface deep
    Science Highlight
    17.06.2024
    MXenes for energy storage: Chemical imaging more than just surface deep
    A new method in spectromicroscopy significantly improves the study of chemical reactions at the nanoscale, both on surfaces and inside layered materials. Scanning X-ray microscopy (SXM) at MAXYMUS beamline of BESSY II enables the investigation of chemical species adsorbed on the top layer (surface) or intercalated within the MXene electrode (bulk) with high chemical sensitivity. The method was developed by a HZB team led by Dr. Tristan Petit. The scientists demonstrated among others first SXM on MXene flakes, a material used as electrode in lithium-ion batteries.