Öffnet in neuem Fenster Opens in a new window Öffnet externe Seite Opens an external site Öffnet externe Seite in neuem Fenster Opens an external site in a new window

Instruments

Please find below the alphabetic list of instruments at BESSY II+.

BESSY II+ Instruments

full operation
limited operation
Test/Inhouse
under construction

InstrumentRemote AccessPhone (~49 30 8062-)Beam availabilityEnergy range (at experiment)PolarisationMethodsContact
Diffraction@KMC-2 Diffraction@KMC-2
not possible14623 24h/d tbd linear horizontal

Powder Diffraction, Single Crystal Diffraction, Surface Diffraction, Anomalous Scattering, Reflectivity, WAXS, Reflectometry

Daniel Többens
XANES@KMC-2 XANES@KMC-2
not possible14623 24h/d tbd linear horizontal

EXAFS, NEXAFS, XRF, XRF Mapping

Götz Schuck
MAXYMUS MAgnetic X-raY Microscope with UHV Spectroscopy
not possible14762 12h/d 200 - 1900 eV horizontal, vertical, circular positive, circular negative

X-ray Microscopy, NEXAFS, XMCD, XMLD, Time-resolved absorption

Markus Weigand
Sebastian Wintz
Simone Raoux
High-Field Diffractometer High-Field Diffractometer@UE46
not possible14717 12h/d 120 - 2000 eV
  • linear any angle (with restrictions)
  • circular

Elastic Scattering, Magnetic Scattering, REXS, XMCD, XMLD, Reflectometry

Eugen Weschke
Enrico Schierle
Oleksandr Prokhnenko
XUV Diffractometer XUV Diffractometer@UE46
not possible14717 12h/d 120 - 2000 eV
  • linear any angle (with restrictions)
  • circular

Elastic Scattering, Magnetic Scattering, REXS, XMCD, XMLD, Reflectometry

Eugen Weschke
Enrico Schierle
Oleksandr Prokhnenko
Spectroscopy@BAMline Nondestructive testing in analytical chemistry
not possible 24h/d tbd horizontal

EXAFS, NEXAFS, XRF, XRF Mapping, XRF, XRF Mapping

Martin Radtke
Ana Guilherme Buzanich
Imaging@BAMline Nondestructive testing in material science
not possible 24h/d tbd horizontal

X-ray Refraction Radiography, X-ray Refraction Tomography, X-ray Tomography

Henning Markötter
FEMTOSPEX-SurfDyn Excited states dynamics with x-rays at UE56_1-PGM
not possible17980, 17981, 17982 24h/d tbd • linear horizontal vertical
• circular

Time-resolved PES, Time-resolved absorption

Nomi Sorgenfrei
Erika Giangrisostomi
Robert Haverkamp
FEMTOSPEX-DynaMax Ultrafast XAS, XMCD, XMRS, and RXD with femtosecond soft x-ray pulses at UE56-1_ZPM
not possible 24h/d tbd variable

Time-resolved diffraction, Magnetic Scattering, Reflectivity, REXS, Time-resolved scattering, NEXAFS, XMCD, XMLD, Time-resolved absorption, Reflectometry, Time-resolved reflection

Christian Schüßler-Langeheine
Niko Pontius
Karsten Holldack
Dirk Ponwitz
CAT CAT@EMIL

(Please contact the Instrument Scientist before applying for experiment time)
not possible12109 12h/d
  • UE48: 80 eV to 2000 eV
  • CPMU17: PGM: 700-1600 eV // DCM: 2200-10000 eV
  • UE48: horizontal, vertical, circular
  • CPMU17: horizontal
  • HAXPES, NAP-XPS, XPS, EXAFS, NEXAFS, Time-resolved absorption, Mass Spectrometry

    Michael Hävecker
    Mihaela Gorgoi
    Stefan Hendel
    Anna Efimenko
    PINK PINK@EMIL

    (Please contact the Instrument Scientist before applying for experiment time)
    not possible12109 12h/d
  • DCM: 2200-10000 eV
  • Multilayer mono: 2300-9500eV
  • horizontal

    XRF


    Mihaela Gorgoi
    Stefan Hendel
    SpAnTeX Spectroscopic Analysis with Tender X-Rays

    (Please contact the Instrument Scientist before applying for experiment time)
    not possible 24h/d 2.4 - 10 keV

    HAXPES, XPS, NEXAFS

    David Starr
    Marco Favaro
    BElChem Berlin Joint Lab for Electrochemical Interfaces @U49-2 PGM

    (Please contact the Instrument Scientist before applying for experiment time)
    not possible14842 24h/d 90 - 2000 eV horizontal

    XPS, EXAFS, NEXAFS, Time-resolved absorption, Mass Spectrometry

    Michael Hävecker
    OAESE Operando Absorption and Emission Spectroscopy at EMIL

    (Please contact the Instrument Scientist before applying for experiment time)
    not possible12109 12h/d
  • UE48: 80 eV to 2000 eV
  • CPMU17: PGM: 700-1600 eV // DCM: 2200-10000 eV
  • UE48: horizontal, vertical, circular
  • CPMU17: horizontal
  • NEXAFS

    Raul Garcia Diez
    Anna Efimenko
    Mihaela Gorgoi
    Stefan Hendel
    SISSY I SISSY I@EMIL
    not possible12109 12h/d
  • UE48: 80 eV to 2000 eV
  • CPMU17: PGM: 700-1600 eV // DCM: 2200-10000 eV
  • UE48: horizontal, vertical, circular
  • CPMU17: horizontal
  • HAXPES, XPS, XRF

    Regan Wilks
    Marcus Bär
    Johannes Frisch
    Anna Efimenko
    Mihaela Gorgoi
    Stefan Hendel
    ENERGIZE ENERGIZE@PM5
    not possible12155 24h/d 20-1700 eV linear horizontal

    ARPES, UPS, XPS, LEED, EXAFS, NEXAFS

    Thorsten Schultz
    GELEM-PES Photoemission@GELEM-Dipole
    not possible 24h/d tbd horizontal

    XPS, NEXAFS

    Anna Makarova
    HE-SGM NEXAFS/XPS spectroscopy @ HE-SGM
    not possible 24h/d tbd horizontal

    XPS, NEXAFS

    Maria Brzhezinskaya
    IRIS THz/IR-spectroscopy
    not possible14716 24h/d tba linearly horizontal/vertical

    IR Microscopy, Mid Infrared near-field Microscopy, THz-near-field Microscopy, IR Spectroscopy, THz spectroscopy, Time-resolved absorption, Polarimetry, Reflectometry, Time-resolved reflection

    Ljiljana Puskar
    Alexander Veber
    IRIS2 IR-microscopy
    not possible14716 24h/d tba linearly horizontal/vertical

    IR Microscopy, Mid Infrared near-field Microscopy, THz-near-field Microscopy, IR Spectroscopy, THz spectroscopy, Time-resolved absorption, Polarimetry, Reflectometry, Time-resolved reflection

    Ljiljana Puskar
    Alexander Veber
    ISISS Innovative Station for In Situ Spectroscopy
    not possible14905, 14906 24h/d tbd linear horizontal

    NAP-XPS, XPS, NEXAFS, Time-resolved absorption, Mass Spectrometry

    Michael Hävecker
    Small Reflectometer@KMC-1 Reflectometry - At-wavelength metrology
    not possible14838 24h/d tbd horizontal

    Reflectivity, NEXAFS, Reflectometry

    Andrey Sokolov
    HiKE High Kinetic Energy Photoelectron Spectroscopy
    not possible14838 tbd horizontal

    HAXPES, NEXAFS, XRF

    Roberto Felix Duarte
    Marcel Mertin
    CryoEXAFS EXAFS station with cryogenic or in-beam, operando electrochemistry sample conditions
    not possible14695 24h/D 3 - 13 keV (extension to 2 keV in progress) horizontal

    EXAFS, NEXAFS, XRF

    Götz Schuck
    Ivo Zizak
    XPP X-Ray Pump Probe (XPP)
    not possible14695 24h/d tbd horizontal

    Time-resolved diffraction

    Matthias Rössle
    Matias Bargheer
    Ivo Zizak
    MX 14.1 Macromolecular Crystallography 14.1
    not possible13432 24h/d tba horizontal

    Crystallography (biological macromolecules), Crystallography (material sciences), Single Crystal Diffraction, Anomalous Scattering

    Manfred Weiss
    Uwe Müller
    Tatjana Barthel
    MX 14.2 Macromolecular Crystallography 14.2
    not possible13432 24h/d tbd horizontal

    Crystallography (biological macromolecules), Crystallography (material sciences), Single Crystal Diffraction, Anomalous Scattering

    Manfred Weiss
    Uwe Müller
    Tatjana Barthel
    MX 14.3 Macromolecular Crystallography 14.3
    not possible13432 24h/d 13.87 keV horizontal

    Single Crystal Diffraction, Crystallography (biological macromolecules)

    Manfred Weiss
    Uwe Müller
    Tatjana Barthel
    mySpot Micro-XANES, -EXAFS, -fluorescence, -SAXS, -WAXS, -Raman Scattering
    not possible14793 24h/d 4 - 25 keV (not all usable for all methods) horizontal

    Fluorescence Imaging, Powder Diffraction, Surface Diffraction, Anomalous Scattering, Elastic Scattering, Reflectivity, SAXS, WAXS, Time-resolved scattering, EXAFS, NEXAFS, XRF, Time-resolved absorption, Reflectometry, Time-resolved reflection

    Ivo Zizak
    Ana Guilherme Buzanich
    Reflectometer@OpticsBL The At-Wavelength Metrology Facility
    not possible14755 24h/d tbd horizontal

    Reflectivity, NEXAFS, Polarimetry, Reflectometry

    Andrey Sokolov
    Franz Schäfers
    Vector Superconducting Magnet VEKMAG
    not possible14834 24h/d tba Circular, Horizontal

    RIXS, XMCD, XMLD

    Florin Radu
    Chen Luo
    Victor Ukleev
    GELEM-PEEM Photoemission Electron Microscope (GELEM)
    not possible13429 24h/d tba • horizontal
    • circular

    PEEM, EXAFS, NEXAFS

    Dmitry Marchenko
    ALICE II Diffractometer/reflectometer for resonant magnetic x-ray scattering applications
    not possible13429 24h/d tbd • horizontal
    • circular

    X-ray Holography, Anomalous Scattering, Coherent Scattering, Elastic Scattering, Magnetic Scattering, Reflectivity, REXS, SAXS, WAXS, NEXAFS, XMCD, XMLD, Reflectometry

    Florin Radu
    Radu-Marius Abrudan
    SoLiAs@PM3 Solid Liquid Analysis System @PM3

    (Please contact the Instrument Scientist (SoLiAs) before applying for experiment time)
    not possible13429 24h/d tbd • horizontal
    • circular

    XPS, LEED, NEXAFS

    Scattering@PM3 Resonant Soft X-ray scattering, NEXAFS, Reflectometry at PM3
    not possible13429 24h/d tbd • horizontal
    • circular

    Magnetic Scattering, Reflectivity, EXAFS, NEXAFS, XMCD

    Torsten Kachel
    Niko Pontius
    LowDosePES LowDosePES@PM4
    not possible14713 24h/d tbd horizontal

    ARPES, UPS, XPS, XPD, Time-resolved PES, NEXAFS, Time-resolved absorption

    Erika Giangrisostomi
    Nomi Sorgenfrei
    THz THz spectroscopy & THz EPR
    not possible13170 24h/D 2 cm-1 - 10000 cm-1 variable

    IR Spectroscopy, Time-resolved absorption, Polarimetry, Reflectometry

    Tarek Al Said
    Karsten Holldack
    Alexander Schnegg
    Dirk Ponwitz
    User station@PM3 Open port dipole beamline (soft X-ray, variable polarisation)
    not possible13429 24h/d 20 - 1900 eV • horizontal
    • circular

    Torsten Kachel
    Dirk Ponwitz
    METRIXS Momentum and Energy resolved RIXS at molecular Systems
    not possible 250 - 1000 eV lin. horizontal

    RIXS, NEXAFS

    Annette Pietzsch
    PEAXIS PhotoElectron Analysis and X-ray Inelastic Spectroscopy
    not possible13154 12h/d 180 eV - 1600 eV (RIXS: 200 eV - 1200 eV) horizontal

    ARPES, XPS, RIXS, EXAFS, NEXAFS

    Deniz Wong
    Bodry Tegomo Chiogo
    TXM Full-field transmission X-ray microscope
    not possible12110 12h/d 180 - 1800 eV (soft X-ray range) & 700 - 2800 eV (tender X-ray range) horizontal

    Fluorescence Imaging, X-ray Microscopy, X-ray Tomography, EXAFS, NEXAFS

    Stephan Werner
    PHARAO PHARAO@U125-2_KMC

    spin-ARPES spin-ARPES at U125_PGM
    not possible14701 12h/d tbd Linear horizontal (fixed)

    ARPES, Spin-resovled PES, UPS, XPS

    Jaime Sánchez-Barriga
    Oliver Rader
    MYSTIIC Microscope for x-raY Scanning Transmission In-situ Imaging of Catalysts

    (Please contact the Instrument Scientist before applying for experiment time)
    not possible 12h/d 80 eV to 2000 eV horizontal, vertical, circular

    X-ray Microscopy, XMCD, XMLD, NEXAFS

    Markus Weigand
    Sebastian Wintz
    Simone Raoux
    Mihaela Gorgoi
    Stefan Hendel
    Anna Efimenko
    SMART Spectro-Microscopy with aberration correction for relevant techniques
    not possible13430 12h/d tbd variable (linear and circular)

    PEEM, X-ray Microscopy, ARPES, UPS, XPS, XPD, Surface Diffraction, XMCD, XMLD, NEXAFS

    Thomas Schmidt
    Marcel Springer
    SPEEM Photoemission Electron Microscope at UE49-PGM
    not possible14750 12h/d tbd variable

    PEEM, X-ray Microscopy, XPS, XMCD, XMLD, Time-resolved absorption

    Florian Kronast
    Sergio Valencia Molina
    Mohamad-Assaad Mawass
    LiXEdrom@PGM-1 LiXEdrom@UE51_PGM-1

    Sol3PES@PGM-1 Sol3PES@UE51_PGM-1

    User station@UE51_PGM-1 User station@UE51_PGM-1

    LiXEdrom@PGM-2 LiXEdrom@PGM-2

    Sol3PES@PGM-2 Sol3PES@PGM-2

    User Station@UE51_PGM-2 User Station@UE51_PGM-2

    CoESCA Coincidence Electron Spectroscopy for Chemical Analysis
    not possible14692 12h/d tbd variable

    ARPES, XPS, XPD, LEED, XPD, XMCD, NEXAFS, Mass Spectrometry

    Danilo Kühn
    Ion Trap Ion Trap@UE52_PGM
    not possible12137 12h/d tbd variable

    XMCD, NEXAFS, Mass Spectrometry

    Vicente Zamudio-Bayer
    Konstantin Hirsch
    AXSYS TES AXSYS Transition Edge Sensor
    not possible13431 12h/d tbd variable

    RIXS, NEXAFS, XMCD, XMLD, EXAFS

    Régis Decker
    Vinícius Vaz da Cruz
    Christian Weniger
    AXSYS NEXAFS Saturation free and time resolved soft X-ray absorption on liquids and colloids
    not possible13431 12h/d 100 - 1100 eV variable

    EXAFS, NEXAFS, Time-resolved absorption

    Lars Birger Mattis Fondell
    Sebastian Eckert
    Vinícius Vaz da Cruz
    Christian Weniger
    meV RIXS High-resolution RIXS of solids in the XUV regime
    not possible14836 12h/d 8 - 690 eV; for extreme values (<50 eV or >400 eV) contact the beamline crew variable

    RIXS, NEXAFS

    Maximilian Kusch
    Katarzyna Siewierska
    ARPES One-Square 1^2 ARPES ultra high resolution photoemission station
    not possible14696 12h/d tbd • linear any angle
    • circular

    ARPES, UPS, XPS, LEED

    Andrei Varykhalov
    ARPES One-Cube 1^3-ARPES ultra high resolution photoemission station
    not possible14696 12h/d tbd • linear any angle
    • circular

    ARPES, UPS, LEED

    Emile Rienks
    Alexander Fedorov

    Back to infrastructure overview

    Beamlines & Insertion devices