• Bahrdt, J.; Frentrup, W.; Gottschlich, S.; Grimmer, S.; Huck, M.; Kuhn, C.; Meseck, A.; Rethfeldt, C.; Scheer, M.; Schulz, B.; Rial, E.C.M.: Characterization and Implementation of the Cryogenic Permanent Magnet Undulator CPMU17 at Bessy II. In: Proceedings of IPAC2019, Melbourne, Australia, 19-24 May 2019Geneva, Switzerland: JACoW Publishing, 2019. - ISBN 978-3-95450-208-0, p. TUPGW014/1415-1418
    http://jacow.org/ipac2019/papers/tupgw014.pdf

Open Access Version

Abstract:
In fall 2018, the cryogenic undulator CPMU17 was installed in BESSY II. Before installation, the undulator was characterized with an in-vacuum Hallprobe bench and an in-vacuum moving wire. Both systems were developed at HZB. The commissioning of the device included the orbit and tune corrections, optimization of the injection, characterization of the heat dissipation, tuning the Landau cavities for a reduction of the heat dissipation in the taper sections (temperatures below 60°C) and testing of the machine protection system. The undulator is ready to deliver light for beamline commissioning. Spectral tuning on a high undulator harmonic (longitudinal taper and alignment of e-beam orbit and undulator axis) will be done as soon as the DCM is operational.