• Neumann, A.; Böhlick, D.; Echevarria, P.; Frahm, A.; Göbel, F.; Kamps, T.; Knobloch, J.; Kugeler, O.; Schuster, M.; Ullrich, J.; Ushakov, A.; Matheisen, A.; Schalwat, M.; Schmökel, M.; Zaplatin, E.; Ciovati, G.; Kneisel, P.: Final Acceptance Test of SRF Photo-injector Cold String for the BERLinPro Energy Recovery Linac. In: Proceedings of LINAC 2016LINAC, 2016. - ISBN 978-3-95450-169-4, p. TUPRC015/1-4
    http://linac2016.vrws.de/papers/tuprc015.pdf

Open Access Version

Abstract:
Helmholtz-Zentrum Berlin (HZB) is currently designing and building an high average current all superconducting CW driven ERL as a prototype to demonstrate low normalized beam emittance of 1 mm mrad at 100 mA and short pulses of about 2 ps. In order to achieve these demanding goals HZB started a staged program for developing this class of required high current, high brightness SRF electron sources. In this contribution we will present the current status of the module assembly and testing of the prototype SRF photoinjector cavity cold string. The steps taken to install the cathode insert system with the cavity in the clean room and the following horizontal test of the cold string as final acceptance test prior installation into its cryostat are shown. First beam in a dedicated diagnostics test stand called Gunlab are planned for this winter.