Dynamic measurements in liquids now possible in the laboratory

The dashed black lines mark the first thin liquid 'sheet' in which the molecules are dissolved. There are two nozzles in the upper part and a collecting vessel in the lower part (left image). Transmission image of the flat jet (centre image). X-ray spectrum of the solution on the CCD detector (right image).

The dashed black lines mark the first thin liquid 'sheet' in which the molecules are dissolved. There are two nozzles in the upper part and a collecting vessel in the lower part (left image). Transmission image of the flat jet (centre image). X-ray spectrum of the solution on the CCD detector (right image). © HZB

A team of researchers in Berlin has developed a laboratory spectrometer for analysing chemical processes in solution - with a time resolution of 500 ps. This is of interest not only for the study of molecular processes in biology, but also for the development of new catalyst materials. Until now, however, this usually required synchrotron radiation, which is only available at large, modern X-ray sources such as BESSY II. The process now works on a laboratory scale using a plasma light source.

"Our laboratory setup now makes this measurement method available to a wider community," says HZB physicist Dr. Ioanna Mantouvalou, who drove the development together with partners from the Technische Universität Berlin, the Max Born Institute, the Physikalisch-Technische Bundesanstalt and the company Nano Optics Berlin. "In a first step, the laboratory measurements can also more precisely define where further analyses at synchrotron sources are useful and promising. This allows us to make better use of scarce resources," says Mantouvalou.

Time-resolved soft X-ray spectroscopy provides access to the properties of organic materials and is therefore ideal for studying dynamic changes in the electronic structure of individual elements in disordered systems. However, measurements of liquid solutions in which these molecules or complexes are dissolved are particularly challenging. They require a high photon flux and extremely low noise. Therefore, these experiments require usually large-scale facilities such as modern synchrotron light sources.

In contrast, the new laboratory instrument uses light from a plasma created by the interaction of an intense laser pulse with metal. The new instrument provides a time resolution of 500 picoseconds and allows a very "stable" detection. "We were able to demonstrate this in our study using two examples in an aqueous solution. We analysed the metal complex compounds [Ni(CN)4]2- and [Fe(bpy)3]2+," says Richard Gnewkow, first author and PhD student in Mantouvalou's team.

arö


You might also be interested in

  • A new way to control the magnetic properties of rare earth elements
    Science Highlight
    17.07.2024
    A new way to control the magnetic properties of rare earth elements
    The special properties of rare earth magnetic materials are due to the electrons in the 4f shell. Until now, the magnetic properties of 4f electrons were considered almost impossible to control. Now, a team from HZB, Freie Universität Berlin and other institutions has shown for the first time that laser pulses can influence 4f electrons- and thus change their magnetic properties. The discovery, which was made through experiments at EuXFEL and FLASH, opens up a new way to data storage with rare earth elements.
  • HZB magazine lichtblick - the new issue is out!
    News
    09.07.2024
    HZB magazine lichtblick - the new issue is out!
    In his search for the perfect catalyst, HZB researcher Robert Seidel is now getting a tailwind – thanks to a ERC Consolidator Grant. In the cover story, we explain why the X-ray source BESSY II plays an important role for his research.

  • BESSY II shows how solid-state batteries degrade
    Science Highlight
    09.07.2024
    BESSY II shows how solid-state batteries degrade
    Solid-state batteries have several advantages: they can store more energy and are safer than batteries with liquid electrolytes. However, they do not last as long and their capacity decreases with each charge cycle. But it doesn't have to stay that way: Researchers are already on the trail of the causes. In the journal ACS Energy Letters, a team from HZB and Justus-Liebig-Universität, Giessen, presents a new method for precisely monitoring electrochemical reactions during the operation of a solid-state battery using photoelectron spectroscopy at BESSY II. The results help to improve battery materials and design.